Mouse neonatal heart
Automated cell counter analytical reporter: Cell viability is 94%. Cell yield is 4.30 x 10^6/100mg.
Mouse liver
Automated cell counter analytical reporter: Cell viability is 95%. Cell yield is 1.60 x 10^6/100mg.
Mouse spleen
Automated cell counter analytical reporter: Cell viability is 96%. Cell yield is 82.00 x 10^6/100mg.
Q1:What are the storage conditions for the tissue enzymatic digestion kit?
A1:Different types of enzymes are contained in different kits, and they should be stored in refrigerators at 4°C or -20°C according to the storage requirements on the instructions.
Q2:What are the storage conditions for the tissue enzymatic digestion kit?
A2:Different types of enzymes are contained in different kits, and they should be stored in refrigerators at 4°C or -20°C according to the storage requirements on the instructions.
Q3:Can the universal tissue enzymatic digestion kit obtain all types of cells from the corresponding tissue?
A3:No, the universal tissue enzymatic digestion kit mainly obtains immune cells, general non-parenchymal cells, and endothelial cells. Hepatocytes, alveolar cells, and other cells cannot be obtained by this kit. In addition, for the extraction of cardiomyocytes, newborn mice/rats of P≤3 within three days of age can be used, but not for P>3.